Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - SNGL POLE
We found 39 results matching your criteria.
Sort By:
1
BR115 15A SINGLE POLE CIRCUIT CIRCUIT BREAKER 1P 1IN 20A BR Homeline Square D CHOM120CP GFCI Circuit Breaker
Eaton's residential BR circuit breakers are used in load centers, panelboards or similar devices. They are made for a wide range of applications and include BR 1 in circuit breakers and accessories for BR-style load centers, arc fault circuit interrupters (AFCI) and ground fault circuit interrupters (GFCI). Switching duty rating. Thermal magnetic 40 deg C. Interchangeable, will replace Bryant, Westinghouse and Challenger. Type BR. 120/240 V, 10,000 AIR. 1 in per pole. Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 20 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating
Homeline Square D CHOM Standard Circuit Breaker BRKR CIRC 15A BLK 120V        BRKR CIRC 20A BLK 120V
Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 15 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Non-interchangeable trip. 120 VAC, 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL listed, HACR rated. 15 and 20 A UL listed for frequent switching applications, 120 VAC fluorescent lighting. 1 in per pole. Non-interchangeable trip. 120 VAC, 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL listed, HACR rated. 15 and 20 A UL listed for frequent switching applications, 120 VAC fluorescent lighting. 1 in per pole.
Qwik Open Square D QO Standard Circuit Breaker Qwik Open Square D QO Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker
All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 30 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating
BREAKER CIRCUT BLACK 1POLE 15A BREAKER CIRCUT BLACK 1POLE 20A BREAKER CIRCUT BLACK 1POLE 30A
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
BRKR CIRC 30A BLK 120V        BQL15 15A SINGLE POLE CIRCUIT BQL20 20A SINGLE POLE CIRCUIT
Non-interchangeable trip. 120 VAC, 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL listed, HACR rated. 15 and 20 A UL listed for frequent switching applications, 120 VAC fluorescent lighting. 1 in per pole. Cutler-Hammer Circuit Breaker, 120/240 VAC, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 1 in H, Includes: Captive Line Screw Cutler-Hammer Circuit Breaker, 120/240 VAC, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 1 in H, Includes: Captive Line Screw
BREAKER DUPLEX PLUGIN 2-1P 15A Federal Pioneer Stab-Lok NC Standard Circuit Breaker Federal Pioneer Stab-Lok NC Standard Circuit Breaker
Eaton Circuit Breaker, Duplex, Type DNPL, 120 VAC, 15 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Independent, Wire Size: 14 to 4 AWG, Terminal Type: Plug-In, Dimensions: 3 in L x 1 in W x 3 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel. Square D Circuit Breaker, NC, 120 V, 20 A, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 12 to 2 AWG Wire, Lug Terminal, 1 Spaces, Plug Mounting, Red, Dimensions: 1/2 in Thick, 40 deg C Operating
Qwik Open Square D QO Standard Circuit Breaker Homeline Square D CHOMT Tandem Circuit Breaker Homeline Square D CHOMT Tandem Circuit Breaker
All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. Square D Homeline Circuit Breaker, Mini, Tandem, 120/240 VAC, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Tandem, 120/240 VAC, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating
BREAKER CIRCUIT 1P 3/4IN 40AMP BREAKER DUPLEX PLUGIN 2-1P 20A BRKR CIRC BLK 15A 120V
All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. Eaton Circuit Breaker, Duplex, Type DNPL, 120 VAC, 20 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Independent, Wire Size: 14 to 4 AWG, Terminal Type: Plug-In, Dimensions: 3 in L x 1 in W x 1 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center Siemens Circuit Breaker, QT, 120 V, 15 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Frame Type: EQ, Frame Size: 1/2 in, Trip Type: Thermal Magnetic, Wire Size: 14 to 6 AWG, Terminal Type: Lug, Plug-In Mounting, Dimensions: 3 in L x 1 in W x 3 in H, Operating Temperature: 40 deg C
Federal Pioneer Stab-Lok NC Standard Circuit Breaker Qwik Open Square D QO Tandem Circuit Breaker BRKR CIRC 40A 30A USE NO8 WIRE
Square D Stab-lok Circuit Breaker, Mini, 120 VAC, 30 A, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 9 AWG Wire, Screw Terminal, Plug Mounting, Dimensions: 3 in L x 0.5 in W x 3.4 in H, 40 deg C Operating All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel.
BREAKER DUPLX BOLT-ON 2-1P 20A Qwik Open Square D QO Tandem Circuit Breaker BRKR CIRC BLK 20A 2 SNGL POLES
Eaton Replacement Classic Circuit Breaker, Duplex, Type BQL, 120 VAC, 20 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Non-Interchangeable, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 3-1/2 in L x 1 in W x 3-1/2 in H, Includes: Captive Line Screw The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip? Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D? exclusive Qwik-Open? protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster. Non-interchangeable trip. For retrofit use on I-T-E load centers built prior to 1965. 120/240 VAC. 1 in per duplex.
QBH15 15A SINGLE POLE CIRCUIT Qwik Open Square D QO Tandem Circuit Breaker QBH20 20A SINGLE POLE CIRCUIT
Eaton Circuit Breaker, QBH, 120 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 10, 12 to 10 AWG, Number of Spaces: 1, Dimensions: 2-3/8 in L x 1 in W x 2-9/10 in H, Operating Temperature: 40 deg C QO (plug-on) and QOB (bolt-on) one-, two- and three-pole thermal-magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. Plug-on QO circuit breakers are for use in QO load centers, NQ and NQOD panelboards, OEM mounting bases and Speed-D? switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQO and NQOD panelboards. Cutler-Hammer Circuit Breaker, 120 V, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Quick-Break, Quick-Make Actuator, Internal Common Trip, 12 to 10, 14 to 10 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 3-1/2 in L x 3 in W x 1 in H
QBH20/QBH30 30A SINGLE POLE CB BREAKER QUAD BOLT-ON 2-1P 15A BREAKER QUAD BOLT-ON 2-1P 20A
Cutler-Hammer Circuit Breaker, 120 V, 30 A, 1 ph, 1 Pole, 10 kA Interrupt, Quick-Break, Quick-Make Actuator, Internal Common Trip, 10 to 1, 10 to 2 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 3-1/2 in L x 3 in W x 1 in H Eaton Replacement Classic Circuit Breaker, Quad Type BQL, 120/240 VAC, 15 A, Number of Phases: 1, Number of Poles: 4, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Independent, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 2 in W, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw Eaton Replacement Classic Circuit Breaker, Quad Type BQL, 120/240 VAC, 15 to 20 A, Number of Phases: 1, Number of Poles: 4, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Independent, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 2 in W, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw
BREAKER QUAD BOLT-ON 2-1P 30A BREAKER QUAD BOLT-ON 2-1P 40A BREAKER CIRC GRDFAULT 120V 15A
Eaton Replacement Classic Circuit Breaker, Quad Type BQL, 120/240 VAC, 15 to 30 A, Number of Phases: 1, Number of Poles: 4, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Independent, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 2 in W, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw Eaton Replacement Classic Circuit Breaker, Quad Type BQL, 120/240 VAC, 15 to 40 A, Number of Phases: 1, Number of Poles: 4, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Independent, Wire Size: 4 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 2 in W, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw Ground fault circuit interrupters are an effective means of preventing severe electrical shock. To protect equipment from damaging ground faults, Siemens GFCIs continuously monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity.
   
 
1